  westcor micropac rev 1.0 vicorpower.com page 1 of 5 8/2012 800 927.9474 product description the micropac is the ?rst westcor product to utilize vicors vi chip technology. the power supply uses bcm modules to provide up to 4 isolated semi regulated output voltages of 12, 24, 36 and 48 vdc and up to 1300 w of continuous power in a very small highly efficient package. the isolated outputs may be placed in parallel/series con?gurations and for applications requiring higher power levels micropac power supplies can be con?gured in ar rays up to several kw. this factory con?gurable rugged power supply supports a wide range of customer power requirements and is especially suited for distributed power architectures. the design offers a small ?exible cost effective solution for applications requiring power factor correction, high efficiency and power density even in environmentally challenging conditions. micropac ac-dc power supply s nrtl cus c us ? high efficiency up to 92% small size high power density > 25 w/in 3 up to 1,300 w > configuration dependent low power standby mode > green mode universal input > 47 to 400 hz > 85 to 264 vac dc input > 120 to 300 vdc up to 4 isolated outputs 12 v output standard 48 v output standard aux isolated 5 v @ 500 ma bias standby supply output parallel capability output series capability output current sharing micropac to micropac current sharing optional power shed capability over temperature warning over temperature shutdown intelligent fan control field replaceable fan individual output enable / disable all output enables / disable capability ttl control signals visual led display panel number of outputs, 1 to 4 cooling f = fan l = -40c fan rohs compliant g = rohs n = non-rohs interface customer option non-safety related s = standard (ttl levels) signaling and control i = digital bus signaling and control contact factory for information regarding digital signaling bus up a - b b b b c d e part numbering output configuration fill in character from chart below for each output b = vout watts b = vout watts a 12 300 g 48 325 b 12 600 h 48 650 c 12 900 i 48 975 d 12 1200 j 48 1300 e 24 600 k 36 900 f 24 1200 m [a] [a] z [b] [b] [a] m defines a slot with an air block filler, no bcm board [b] z indicates the slot is populated with a bcm board that is connected in series or parallel with the adjacent slot examples: up1-fzzz-fsg denotes a single output of 24 v 1200 w with a standard fan, standard ttl signaling and control, rohs compliant up4-aaaa-lsn denotes 4 output unit, each output is 12 v 300 w. the fan is a -40c capable unit, standard ttl signaling, and the unit is non-rohs
westcor micropac rev 1.0 vicorpower.com page 2 of 5 8/2012 800 927.9474 input input voltage 85 ? 264 vac dc rating: 120 vdc ? 300 vdc (?? x 1??) cooper bussmann, (5 x 20 mm) littelfuse, abc-15, 216 series, external fuse rated 15 a rated 16 a littelfuse, (?? x 1??) littelfuse, 505 series, 505 series, rated 16 a / 500 vdc rated 16 a / 500 vdc frequency 47 ~ 400 hz inrush current 30 a peak efficiency 92% @ full load @ 25c 91% @ full load @ 25c ambient 48 v output ambient 12 v output power factor > 0.95 typ. meets en61000-3-2 turn-on time ac on 1.5 sec typ en55022 class b information technology equipment ? radio conducted emi disturbances characteristics ? limits and methods of measurement bs en55022:1998; cispr 22:1997, incorporating corrigendum harmonic distortion meets iec 61000-3-2 isolation meets iec 60950 leakage current < 3.5 ma @ 264 vac @ 63 hz hold up time 20 ms typical warranty 2 years output number of outputs 1 to 4 normal output voltages 12 v, 24 v, 36 v and 48 v (contact factory for details) maximum output current 100 a @ 12 v [27 a @ 48 v] auxiliary output 5 v @ 0.5 a 50 mv p-p voltage regulation 12 v output (11.3 v ~ 12.5 v) 48 v output (45 v ~ 50 v) ripple and noise 12 v output (197 mv ~ 400 mv p-p) 48 v output (1.6 vp-p) (20 mhz bandwidth) current sharing accuracy 5 to 10% short circuit protection ?fold-back? technique over voltage protection 12 v output set point 12.5 v typical 48 v modules 50 v typical thermal protection all outputs disabled when internal temperature exceeds safe operating maximum load 12 v up to 1200 w maximum load 48 v up to 1300 w maximum load 5.0 v aux up to 2.5 w maximum load capacitance 1000 f per 12 v output 100 f per 48 v output specifications
westcor micropac rev 1.0 vicorpower.com page 3 of 5 8/2012 800 927.9474 environmental storage temperature -40c ~ +85c operating temperature -20c ~ +55c (extended temperature range is available; -40c to +55c) functional shock mil-std 810f method 516.5 procedure 1, terminal peak saw-tooth wave, 40g 11 ms vibration mil-std 810g for minimum integrity vibration humidity 95% non condensing cooling fan cooled (field replaceable) temperature speed control electromagnetic compatibility en61000-6-1n european general emc immunity iec 61000-4-11 [50 hz] voltage dips 30% for 0.5 prd, pc c voltage interrupts (pc c) iec 61000-4-4 [transient] eft / burst 1 kv ac leads 500 v dc leads. 5 / 50 nsec 5 khz rep rate (pc b) iec 61000-4-5 [surge] power line surge ac in 2 kv cm 1 kv dm dc in 500 v cm & dm 1.2 / sec (pc b) en 61000-4-6 [0.15 to 80 mhz] rf common mode input leads, ac & dc leads, cdn 150 khz to 80 mhz, 3 vrms with 80% am @1 khz (pa a) en 61000-4-2 [electrostatic] electrostatic discharge 4 kv contact 8 kv discharge (pc b) en 61000-4-3 rf e-field 80 mhz to 1 ghz 3 v/m with 80% am @ 1 khz (pc a) en 61000-4-8 power freq h-field 3a / m @ 50 hz (pa a) reliability fit tbd service life 5 years safety & regulatory ul ul 60950-1:2007 can c22.2 no. 60950-1-07 csa csa*60950 3rd edition (cb report to include all national deviations) en en 60950-1/a1:2010 iec 60950-1-2005 2 ed. +a1:2009 specifications (cont.)
westcor micropac rev 1.0 vicorpower.com page 4 of 5 8/2012 800 927.9474 0 0 .500 5.800 1.329 0 0 1.329 5.800 2x .500 1.72 0 0 2x 1.325 4.00 7.38 7.44 7.45 .19 .287 .502 3.502 3.542 2x 6.486 0 0 1.000 .500 0 0 2x 1.329 2x 5.863 .312 .644 3.356 3.688 2x customer mounting . use crimp tool from molex p/n - 11-01-0199 for j5 4. use screw #6-32 . maximum intrusion of screw into chassis 7 3.1 1 9 1. 3.2 interpret drawing per ansi y14.5-1994. notes: unless otherwise specified 2 4 . use crimp tool from fci p/n - ht-151 or rcy21151 for j2 from outside surface of chassis = .125" air flow 10 12 3 11 ch-1 5 . westcor mating connectors kit p/n 19-130066. output power connector pin number function 1+5 volt 20 volt 3 enabled/disabled - 1 4 over temperature warning 5 enabled/disabled - 3 6 a/c okay 7 standby mode 8 general shutdown 9fan fault 10 enabled/disabled - 2 11 not connected 12 enabled/disabled - 4 ch-3 ch-2 ch-4 see detail-a for pinout a 4 4 2x customer mounting 4 4x customer mounting ground chassis #6-32 chassis ground 3.2 use screw size live neutral j5 4x customer mounting 4 6 8 4 scale 8 : 1 j2 2 detail a see note - 2, 3.1 mechanical drawings figure 1: physical dimensions and electrical connections
westcor micropac rev 1.0 vicorpower.com page 5 of 5 8/2012 800 927.9474 vicor corporation 25 frontage road andover, ma, usa 01810 tel: 800-735-6200 fax: 978-475-6715 email customer service: custserv @vicorpower.com technical support: apps@vicorpower.com vicor?s comprehensive line of power solutions includes high density ac-dc and dc-dc modules and accessory components, fully configurable ac-dc and dc-dc power supplies, and complete custom power systems. information furnished by vicor is believed to be accurate and reliable. however, no responsibility is assumed by vicor for its use. vicor makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication. vicor reserves the right to make changes to any products, specifications, and product descriptions at any time without notice. information published by vicor has been checked and is believed to be accurate at the time it was printed; however, vicor assumes no responsibility for inaccuracies. testing and other quality controls are used to the extent vicor deems necessary to support vicors product warranty. except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. specifications are subject to change without notice. vicor?s standard terms and conditions all sales are subject to vicors standard terms and conditions of sale, which are available on vicors webpage or upon request. product warranty in vicors standard terms and conditions of sale, vicor warrants that its products are free from non-conformity to its standard specifications (the express limited warranty). this warranty is extended only to the original buyer for the period expiring two (2) years after the date of shipment and is not transferable. unless otherwise expressly stated in a written sales agreement signed by a duly authorized vicor signatory, vicor disclaims all representations, liabilities, and warranties of any kind (whether arising by implication or by operation of law) with respect to the products, including, without limitation, any warranties or representations as to merchantability, fitness for particular purpose, infringement of any patent, copyright, or other intellectual property right, or any other matter. this warranty does not extend to products subjected to misuse, accident, or improper application, maintenance, or storage. vicor shall not be liable for collateral or consequential damage. vicor disclaims any and all liability arising out of the application or use of any product or circuit and assumes no liability for applications assistance or buyer product design. buyers are responsible for their products and applications using vicor products and components. prior to using or distributing any products that include vicor components, buyers should provide adequate design, testing and operating safeguards. vicor will repair or replace defective products in accordance with its own best judgment. for service under this warranty, the buyer must contact vicor to obtain a return material authorization (rma) number and shipping instructions. products returned without prior authorization will be returned to the buyer. the buyer will pay all charges incurred in returning the product to the factory. vicor will pay all reshipment charges if the product was defective within the terms of this warranty. life support policy vicors products are not authorized for use as critical components in life support devices or systems without the express prior written approval of the chief executive officer and general counsel of vicor corporation. as used herein, life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the user. a critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness. per vicor terms and conditions of sale, the user of vicor products and components in life support applications assumes all risks of such use and indemnifies vicor against all liability and damages. intellectual property notice vicor and its subsidiaries own intellectual property (including issued u.s. and foreign patents and pending patent applications) relating to the products described in this data sheet. no license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property rights is granted by this document. interested parties should contact vicor's intellectual property department.


▲Up To Search▲   

 
Price & Availability of A-BBBBCDE

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X